Mfg Part Number: 17028401 | NSN : 5950-00-426-2675 | NIIN : 004262675 |
CAGE Code : 85323 | Manufacturer: Baltimore Transformer Company | Item Name : Transformer Power |
FSC : 5950 Coils and Transformers |
At Aerospace and Defence Parts, we offer high-quality NSN Part 17028401 that you can steadily rely on for your applications. NSN 5950-00-426-2675 of 17028401 is listed alongside and it has been manufactured by Baltimore Transformer Company. As we have availability for Transformer Power parts now, we invite you to fill out and submit the form provided below to request a quote for your comparisons. As you complete our form, we recommend that you provide us with as much information as you can regarding your desired 17028401 Part, quantities, target price, expected shipping time frame, and more so that we may best tailor a solution fit for you.
NSN 5950-00-426-2675 with NIIN is manufactured under the CAGE Code 05305, and we list our parts with such information to ensure that you always procure the exact items that you require. Additionally, our industry experts offer person-to-person communication every step of the purchasing process so that your requirements are thoroughly met. If you are facing a time constraint and need components quickly, our supply chain network stretching across the United States, Canada, and the United Kingdom enables us to provide rapid shipping times for your benefit. Experience the future of part procurement today when you get in contact with one of our representatives.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-426-2675 Item Description: Transformer Power | 5950 | 004262675 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
17028401 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.063 INCHES NOMINAL3.063 INCHES NOMINAL3.063 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.625 INCHES NOMINAL2.625 INCHES NOMINAL2.625 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.250 INCHES NOMINAL4.250 INCHES NOMINAL4.250 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 50.0 DEG CELSIUS50.0 DEG CELSIUS50.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED WITH OILHERMETICALLY SEALED WITH OILHERMETICALLY SEALED WITH OIL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 15.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 18.5 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 25.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY330.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY6.30 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY6.30 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 330.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY330.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 35.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY35.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 15 TURRET |